1/1/30 On On 6385 7000 802.3af Class 2 3 n/a
1/1/31 On On 6385 7000 802.3af Class 2 3 n/a
1/1/32 On On 6385 7000 802.3af Class 2 3 n/a
1/1/33 On On 6291 7000 802.3af Class 2 3 n/a
1/1/34 On On 6291 7000 802.3af Class 2 3 n/a
1/1/35 On On 6291 7000 802.3af Class 2 3 n/a
1/1/36 On On 6291 7000 802.3af Class 2 3 n/a
1/1/37 On On 6291 7000 802.3af Class 2 3 n/a
1/1/38 On On 6385 7000 802.3af Class 2 3 n/a
1/1/39 On On 6291 7000 802.3af Class 2 3 n/a
1/1/40 On On 6291 7000 802.3af Class 2 3 n/a
1/1/41 On On 6385 7000 802.3af Class 2 3 n/a
1/1/42 On On 6479 7000 802.3af Class 2 3 n/a
1/1/43 On On 6385 7000 802.3af Class 2 3 n/a
1/1/44 On On 6479 7000 802.3af Class 2 3 n/a
1/1/45 On On 6291 7000 802.3af Class 2 3 n/a
1/1/46 On On 6385 7000 802.3af Class 2 3 n/a
1/1/47 On On 6385 7000 802.3af Class 2 3 n/a
1/1/48 On On 6385 7000 802.3af Class 2 3 n/a
--------------------------------------------------------------------------
Total 306950 336000
Syntax: show inline power [device/slot/port]
Field definitions for the show inline power command TABLE 43
Column Definition
Power Capacity The total PoE power supply capacity and the amount of available power (current free) for PoE
power consuming devices. Both values are shown in milliwatts.
Power
Allocations
The number of times the device fulfilled PoE requests for power.
Port The slot number and port number.
Admin State Specifies whether or not Power over Ethernet has been enabled on the port. This value can be
one of the following:
• On - The inline power command was issued on the port.
• Off - The inline power command has not been issued on the port.
Oper State Shows the status of inline power on the port. This value can be one of the following:
• On - The PoE power supply is delivering inline power to the PD.
• Off - The PoE power supply is not delivering inline power to the PD.
• Denied - The port is in standby mode (waiting for power) because the device does not
currently have enough available power for the port.
NOTE
When you enable a port using the CLI, it may take 12 or more seconds before the operational
state of that port is displayed correctly in the show inline power output.
Power
Consumed
The number of current, actual milliwatts that the PD is consuming.
Power
Allocated
The number of milliwatts allocated to the port. This value is either the default or configured
maximum power level, or the power class that was automatically detected by the device.
Power over Ethernet
360 FastIron Ethernet Switch Administration Guide
53-1003625-01

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Brocade Communications Systems FastIron and is the answer not in the manual?

Brocade Communications Systems FastIron Specifications

General IconGeneral
BrandBrocade Communications Systems
ModelFastIron
CategorySwitch
LanguageEnglish

Related product manuals