22 Brocade MLX Series and NetIron XMR Hardware Installation Guide
53-1003821-01
Router modules
1
You must insert XFP-compliant fiber-optic transceivers in each port you intend to use.
XFP-compliant transceivers provide an optical or physical medium-dependent (PMD) interface for
single- or multi-mode fiber that can be used with either the LAN physical layer (PHY) or WAN
physical layer (WAN PHY).
For an up to date list of the 10 Gbps XFP-compliant fiber-optic transceivers that are available from
Brocade, refer to the latest version of the Brocade Optics Family Data Sheet, available online in the
following location:
http://www.brocade.com/downloads/documents/data_sheets/product_data_sheets/optics-famil
y-ds.pdf
For more information about fiber-optic transceivers and associated cabling, refer to “Installing a
fiber-optic transceiver” on page 218.
Power supply requirements for 10Gx4 interface modules
For power supply requirements for the 10Gx4 modules, refer to Chapter 8, “Hardware
Specifications”.
8-port 10 Gbps M and D interface modules
The 8-port, 10 Gbps interface modules (NI-MLX-10Gx8-M and NI-MLX-10Gx8-D) provide eight 10
Gbps ports that support SFP+ optics. These modules contain an internal flash memory of 16 MB
for local storage of CPU images, and 32 MB for local storage of FPGA images. The NI-MLX-10Gx8-M
interface module supports a buffer of 3 GB buffering per module. The NI-MLX-10Gx8-D module
supports 1 GB buffering per module.
NOTE
NI-MLX-10Gx8-M and NI-MLX-10Gx8-D modules are designed for use with Brocade MLX routers only.
They are not supported for NetIron XMR routers.
NOTE
When installing NI-MLX-10Gx8-M or NI-MLX-10Gx8-D modules, you must first upgrade the software
on all interface modules and management modules to Multi-Service IronWare software R05.0.00 or
later. For more information, refer to the Hardware Installation Notes that shipped with the modules.
NOTE
NI-MLX-10Gx8-D interface modules do not support MPLS.
NOTE
NI-MLX-10Gx8-M or NI-MLX-10Gx8-D modules require high-speed switch fabric modules to operate.
You can replace switch fabric modules with high-speed switch fabric modules while the system is
powered on and running. For more information about high-speed switch fabric modules, see
“High-speed switch fabric modules” on page 33.
For Brocade MLX 16-slot routers, NI-MLX-10Gx8-M and NI-MLX-10Gx8-D modules require the
installation of high-speed fans in addition to high-speed switch fabric modules. For information
about the high-speed fans, see “NIBI-16-FAN-EXH-A high-speed fan assemblies” on page 40.
Figure 16 displays the faceplate of the NI-MLX-10Gx8-M and NI-MLX-10Gx8-D modules. Figure 17
shows the RX and TX orientation for the ports, and identifies which LED goes with which port.
FIGURE 16 NI-MLX-10Gx8-M and NI-MLX-10Gx8-D module faceplate

Table of Contents

Other manuals for Brocade Communications Systems MLX Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Brocade Communications Systems MLX Series and is the answer not in the manual?

Brocade Communications Systems MLX Series Specifications

General IconGeneral
BrandBrocade Communications Systems
ModelMLX Series
CategoryNetwork Router
LanguageEnglish

Related product manuals