4 – 32 Repair Manual RRE140/160/180/200/250 © BT
Functions and parameters
Operation and connection sequences
T-code Valid from serial number Date Publication No.
815, 816 6051502 2008-08-21 261828-040
Event: 2c. Login via "ID key" option
Previous event 1. Battery is connected
Action(s) The operator presses the green button and then, within 5 seconds,
passes the ID key over the scanner.
Contributing factors Parameter 503 = ‘7’ or ‘8’
"Central Information Display (CID)" displays a key symbol when the
truck is in logged-out mode:
Once the green button has been pressed, it is possible during a 5 sec-
ond period to log in with the ID key. The following is displayed:
Resulting conditions Login approved:
“Central Information Display (CID)” displays a status image for
approximately
2 seconds:
Main contactor [Q10] on
Key relay [K20] on
Login rejected:
“Central Information Display (CID)” displays:
Main contactor [Q10] off
Key relay [K20] off