Functions and parameters
Lifting devices
Publication No. Date Valid from serial number T-code
261828-040 2008-08-21 6051502 815, 816
© BT Repair Manual RRE140/160/180/200/250 4 – 67
The identification plates of the telescopic forks have had an L and an R
added to them. The forks are fitted on the left and right fork holder,
respectively, as viewed from the operator seat. The forks are pushed up
on the fork holder so that the locking catch fits in the holder recess.
Along the rear of the fork holder there is a distribution valve.
The maximum fluid pressure for the telescopic forks is 20 MPa (200
bar).