SMART KTF 2000 – KTF/RW Operation
SMART KTF 2000 3B-33 -
Example:
1.5) MAIN TENSION= 10g
1.6) TENS INC-DEC= 0,1g
1.7) METR INC-DEC= +000100 m.
1.8) METR TARGET= 10000 m.
The initial tension (10g) is increased by 0.1g every 100 metres; when reaching the target (10000m) it
returns to 10g.
For more details and application examples, please refer to KTF/RW
Operating Manual.
Press to enable the parameter programming
OFF= Function disabled; to enable it press and hold down
for 3 seconds
+ = Increment
- = Decrement
Press and hold down
for 3 seconds to switch from + to – or
for – to OFF.
Set the desired value: every how many meters the MAIN TENSION (P1.1) value
must be increased/decreased by the amount specified by METR INC-DEC (P1.5)
parameter.
increases the value by 1
decreases the value by 1
+ increases the value by 1000
+ decreases the value by 1
After having set the desired value, press
to continue