SMART KTF 2000 – KTF/100HP Operation
3A-26 SMART KTF 2000
If you try to enter a name already existing, the warning message DOUBLE NAME,
will be displayed. In this case, press
and enter a new name.
Press
to start the parameters settings.
aaaaaaa = name of article previously set up
nn = number of KTF devices associated to aaaaaaa article.
Choose the desired value using
.
Press
to continue.
On all the screens of the NEW function, the upper row of display will always
indicate the progressive parameter number N), followed by the name of that
parameter.
Using
, you can directly select the desired parameter.
Using
you can select and confirm in sequence all the parameters.
1) MAIN TENSION = MAIN * TENSION
Press
to enable the parameter programming.
VV.V = Value of MAIN * TENSION parameter to be associated to the article
setup.
Choose the desired value using
, ,
[allowed values: from 0.1 to 99.9 grams].
Press
to move to the next parameter.
2) ERR TENSION = ERROR TENSION
MODE 04
MODE 04MODE 04
MODE 04
Press
to enable the parameter programming.
VV.V = Value of ERROR TENSION parameter to be associated to the article
setup. It indicates the Tolerance Range of Tension beyond which the
machine will be stopped. The error signalling as well as the machine stop
occur only if the tolerance is exceeded for the period of time indicated by
the next parameter 3) TIME ALARM.
Choose the desired value using
, ,
[allowed values 0.1 (value of MAIN TENSION parameter)].
Press
to move to the next parameter.