3) TIME ALARM = TIME ALARM
MODE 04
MODE 04MODE 04
MODE 04
Press
to enable the parameter programming
VV.V = Value of TIME ALARM parameter to be associated to the article setup. It
indicates the maximum time (in seconds) during which the tension value
may exit from the tolerance range set by the 2) ERR TENSION
parameter. You can disable (OFF) or re-enable this feature by pressing
.
Choose the desired value using
, ,
[allowed values: 0.1 to 10 sec.].
Press
to move to the next parameter.
4) IN-DE TENSION = INC-DEC TENSION
Press
to enable the parameter programming
VV.V = Value of INC-DEC TENSION parameter to be associated to the article
setup. It indicates the increment/decrement resolution of the Tension
graduated by the external INC/DEC command pulses.
Choose the desired value using
, ,
[allowed values: 0.1 to 25 grams].
Press
to move to the next parameter.
5) EXIT TENSION = EXIT * TENSION
Press
to enable the parameter programming
VV.V = Value of EXIT * TENSION parameter, i.e. the tension value of the
device when the machine is stationary or out of the yarn working zone
with INC/DEC de-activated. If you set a value greater then or lower then
the value set with MAIN TENSION parameter you may control the
deceleration phase of KTF device. This parameter can be enabled (setting
a value ranging from 0.2 to 100 g) or disabled (OFF) using the
CONTROL button.
When it is disabled, it assumes the value previously set with 1) MAIN TENSION
parameter.
Press
to move to the next parameter.