7-MAINTENANCE
Initial100hours
Changeengineoilandlter(Initial)
Changetheengineoilandlterwhenthehourmeterregisters100hoursforanewmachineduringtheinitialrun-in
period.Theengineoilandltershouldbechangedevery500hoursthereafterormorefrequentlywhentheengine
operatingconditionsaresevere.
Prioroperation:
Keepallunauthorizedpersonnelclearofthearea.Parkthemachineonlevelground,inneutralwiththeparking
brakeapplied,andtheattachmentloweredtotheground.Makesurethatallresidualpressureisrelievedfromcircuits
beforebeginningmaintenance.
Servicespecications
TypeofoilCASEAKCELAUNITEKNO.1™SBLCJ-4SAE
10W-40
Capacity(withlterchange)16.4l(17.3USqt)
Capacity(withoutlterchange)15.6l(16.5USqt)
1.Opentheleftfrontandrightfrontaccessdoorandse-
curewithdoorstrut.
2.Oilwilldrainfasteriftheoiliswarm(nothot)andthe
dipstick(1)isremoved.
3.Useasuitablecontainertocollectthedrainedoil.
RAIL13DOZ1693AA1
4.Removetheboltsthatsecuretheengineoilaccess
plateundertheengine.
RAPH12DOZ0095AA2
NOTE:Ifthemachineissoequipped,andthespecialdrainingequipmentisavailable,usetheengineenvironmental
drainlocatedintheleftsideengineaccessdoor.
7-45