B) Fast-speed cylinder mold-opening as the 2
nd
step to quickly open the molds.
Either the standard mold-opening method or the hydraulic pressure loop
differentiated method can be applied in this step. If you choose the hydraulic
pressure loop differentiated method, please move to
Function selection
for
super fast mold-opening will speed up.
However, parameter
MM
has to be set
above 70% to execute this function.
C) Fast-speed cylinder decelerated mold-opening as the 3
rd
step.
2.5.3.8 Special Function Setup
The setup for function selection: move the cursor to “
” “
”and “
”, press either
or
for “open “or ”close “
Code descriptions for function selection are as follows:
D) j:Function selection for fast-speed cylinder fast mold-opening.
E) k:Spare function selection.
F) l:Function selection for mold opening and closing of fast-speed cylinder
special mold. Code descriptions for parameters of the special mold are as follows:
F.a) WWWW.W :Mold-closing start-position setup for fast-speed cylinder special
mold.
F.b) ZZZ.Z :The moving distance setup for mold closing of fast-speed cylinder
special mold.
F.c) XX :Mold-closing speed setup for fast-speed cylinder special mold.
F.d) YY :Mold-closing pressure setup for fast-speed cylinder special mold.
F.e) aaaa.a :Mold-opening start-position setup for fast-speed cylinder special
mold.
F.f) ddd.d :The moving distance setup for mold opening of fast-speed cylinder
special mold.
F.g) bb :Mold-opening speed setup for fast-speed cylinder special mold.
F.h) cc :Mold-opening pressure setup for fast-speed cylinder special mold.