CDC-2000
操作手冊
Operational Manual
2.7.4. Sequence Diagram of Auto Motion
Ejector
forward
Ejector
backward
JJ
KK GG
HH
Optic meter (enc3
) Position setup
III.I
LLL.L FFF.F
Ejector operational cycle
Stop-operation in ejector forward
Ejector umber
CNT0=1
AA
BB DD
EE
Ejector forward
Ejector
backward
Ejector umb
er CNT0=2
III.I
LLL.L FFF.F
Ejector halt time (0000.0)
JJ
KK GG
HH
AA
BB DD
EE
AA
BB DD
EE
JJ
KK GG
HH