1 Operational Manual
2.11.3.1 Move cursor to set parameter, key in desired digits and press to complete
a correction. Code descriptions for Menu (09) are listed below:
A) AAAAAAAAAAAAAAA: Not used.
B) BBBBBBBB: Not used.
C) CCCCCCCC: Not used.
D) PPPP.P: Not used.
E) DDDD.D: Not used.
F) L: Not used.
G) EEEEE: Not used.
H) KKKKK: Not used.
F) M : Not used.
2.11.3.2 Manual Operation For Mold Thickness Adjustment:
A) In Menu (09),mold is hung on the mechanism, to adjust the counter position and
press for clamping on Menu (33)
carriage cylinder mold adjustment II
JJ
don
t loose the button in the mold-closing interval until the basks is
finished.。
B) In Menu (09), press for mold-open on Menu (33)
carriage cylinder mold
adjustment II JJ
; don
t loose the button in the mold-opening interval until
is finished.
2.11.3.3 Automatic Mold-Closing:
In Menu (09), mold is hung on the mechanism, to adjust the cursor position and press
for auto mold-closing adjustment.
A) In Menu (33),
carriage cylinder mold adjustment II JJ
for mold closing.
B) After the mold closes of fast-cylinder, adjustment will be stop.
C) After the check of teeth, split nuts tight till the limit switch confirmed, then
take off the mold-rings.
04/08/13