1 Operational Manual
stroke setting of injection 3 will be recalculated according to its percentage.
Q) LL: Stroke setting of injection 3. Plasticizing end-position equals 100%. Key in
desired digits and press to complete a correction. If desired digits are
keyed in and
are pressed, the position set value of injection 3 will be
recalculated according to its percentage.
R) MM: Speed setup for injection 4.
S) NN: Pressure setup for injection 4.
T) OOO.O: End-position setup for injection 4. Key in desired digits and, press
to complete a correction. If desired digits are keyed in and
are pressed,
stroke setting of injection 4 will be re-calculated according to its percentage.
U) PP: Stroke setting of injection 4. Plasticizing end-position equals 100%. Key in
desired digits and press
to complete a correction. If desired digits are
keyed in and
are pressed, portion set value of injection 4 will be
re-calculated according to its percentage.
V) QQ: Speed setup for injection 5.
W) RR: Pressure setup for injection 5.
X) SSS.S: End-position setup for injection 5. Key desired digits and press to
complete a correction. If desired digits are keyed in and
is pressed, stroke
setting of injection 5 will be re-calculated according to its percentage.
Y) TT: Stroke setting of injection 5. Plasticizing end-position equal 100%. Key is
desired digits and press
to complete a correction. If desired digits are
keyed in is pressed, the position set value of injection 5 will be
recalculated according to its percentage.
Z) UU: Speed setup for injection 6.
AA)VV: Pressure setup for injection 6.
BB)WWW.W:
Stroke setting for injection 6,i.e., holding pressure stroke switched from
injection stroke. Whatever the injection time, key in desired digits and press
to complete a correction. If is pressed, stroke setting of injection
6 will be recalculated according to its percentage.
CC)XX: Strode setting of injection 6, i.e., holding pressure stroke switched from
injection stroke. Plasticizing end-position equals 100%. Key in desired digits
and press to complete correction. If desired digits are keyed in and
is pressed, the position set value of injection 6 will be recalculated according
04/08/13