Loading...
11-30
Cisco ASR 1000 Series Aggregation Services Routers Hardware Installation Guide
OL-13208-11
Chapter 11 Cisco ASR 1013 Router Overview and Installation
Connecting Power to the Cisco ASR 1013 Router
Figure 11-13 shows the Cisco ASR 1013 Router AC power supply.
Figure 11-13 Cisco ASR 1013 Router AC Power Supply
Note Shielded cables must be used to connect to the DB-25 alarm connector on both the AC and DC
power supplies in order to comply with FCC/EN55022/CISPR22 Class A emissions
requirements. See the “How Cisco ASR1000-RP Alarm Monitoring Works” section on
page 2-20.
Step 3 Plug the AC power supply cable into the AC power source.
This completes the procedure for connecting AC-input power.
1 AC power supply fan 6 AC power inlet
2 DB-25 alarm connector 7 AC power supply Standby switch
3 Tie-wrap tab 8 Protective shielding on both sides of the Standby
switch
4 AC power supply captive screw 9 AC power supply LEDs
5 AC power supply handle
253916
OUTPUT INPUT INPUT
FAIL OK OK
ALARMS
60V
1A MAX
100-240V~ 16-7A
50-60HZ
This unit might have more than
one power supply connection.
All connections must be removed
to de-energize the unit.
2 13
4
5
6 7
9
8