Table 58: +24 VDC Output Voltage Alarm Threshold Ranges
MaximumMinimumOutput
12.8-13.8V10.0-11.2V12V
None
2.6 – 3.0V
3.3V
• Temperature—If a single fan fails, the power supply meets the functional requirements specified in
Table 24. Above 55°C with less than two fans, calculated MTBF does not apply; however all component
stress remains within the manufacturer’s specified rating.
• Thermal Shutdown—The +24 VDC power supply will shut down to protect its components due to
excessive internal temperature. The +24 VDC power supply then automatically restarts if the internal
temperature returns to a safe operating level.
Power Cords Supported by the Cisco ASR 1002 Router
The following table lists the power cords that are supported by the Cisco ASR 1002 Router.
Table 59: Power Cords Supported by the Cisco ASR 1002 Router
DescriptionPower Cord Item Number
Power Cord, 110 V, Right AngleCAB-AC-RA
Plug, Power Cord, Australian, 10 A, Right AngleCAB-ACA-RA
Power Cord, Brazil, Right Angle, 10 ACAB-ACB10A-RA
Power Cord China, Right AngleCAB-ACC-RA
Power Cord Europe, Right AngleCAB-ACE-RA
Power Cord, Italian, Right AngleCAB-ACI-RA
Power Cord Argentina, Right AngleCAB-ACR-RA
Power Cord, Switzerland, Right AngleCAB-ACS-RA
Power Cord UK, Right AngleCAB-ACU-RA
Power Cord India, Right AngleCAB-IND-RA
Power Cord-Japan, Right AngleCAB-JPN-RA
Cisco ASR 1000 Series Router Hardware Installation Guide
233
Cisco ASR 1002 Router Overview and Installation
Power Supplies in the Cisco ASR 1002 Router