EasyManuals Logo

Cisco Catalyst 4500 Series Message Guide

Cisco Catalyst 4500 Series
146 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #132 background imageLoading...
Page #132 background image
2-112
Catalyst 4500 Series Switch Cisco IOS System Message Guide Release 12.2(31)SGA
OL-11541-01
Chapter 2 Messages and Recovery Procedures
SWITCHINGENGINEMAN Messages
Error Message C4K_SWITCHINGENGINEMAN-3-PACKETMEMORYERROR2: Multiple Errors in
Packet Memory [dec]
Explanation
Multiple errors in packet memory were detected. If this message persists, it might
indicate a hardware problem.
Recommended Action If this message persists, use the show platform commands to show results,
contact your technical support representative, and provide the representative with the gathered
information.
Error Message C4K_SWITCHINGENGINEMAN-3-PACKETMEMORYPARITYERROR: Parity error in
Packet Memory at address [dec] , total errors= [dec]
Explanation
There is a parity error in packet memory. This condition might indicate a transient
hardware problem or a more permanent problem. After 128 packet memory and queue memory
errors, the switch reloads automatically.
Recommended Action If this message reoccurs, reboot the switch. If the message appears every time
the switch boots, run the show diagnostics online command and send the results to your technical
support representative.
Error Message C4K_SWITCHINGENGINEMAN-3-PACKETMEMORYTESTFAILURE:Packet Memory buffer
test failed!!! Insufficient packet buffers are available to continue booting.
Explanation
The packet memory diagnostic bootup test detected too many failures for switch
operation to continue.
Recommended Action Refer to the Release Note attachment in the DDTS for CSCdz57255.
Error Message C4K_SWITCHINGENGINEMAN-3-PACKETMEMORYTESTPARTIALFAILURE:Packet Memory
buffer test detected errors with [dec] % of the packet buffers. Switch operation
will continue, with potentially reduced performance. Use 'show diagnostic result
module all detail' command to see test results.
Explanation
The packet memory diagnostic bootup test detected failures, but there are still a
sufficient number of working buffers to enable switch operation.
Recommended Action Use the show diagnostic result module all detail command to see the test
results. Refer to the Release Note attachment in the DDTS for CSCdz57255.
Error Message C4K_SWITCHINGENGINEMAN-3-PPECELLDUPDETECTED: Free cell duplicate(s)
detected [hex]. System will be reset!
Explanation
The system detected free cell duplication, and will be reset. This message may also
erroneously appear when using jumbo packets or if sharing is configured and transmit queues have
backed up.
Recommended Action This is an informational message only. No action is required.

Table of Contents

Other manuals for Cisco Catalyst 4500 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Catalyst 4500 Series and is the answer not in the manual?

Cisco Catalyst 4500 Series Specifications

General IconGeneral
SeriesCatalyst 4500 Series
CategorySwitch
Layer SupportLayer 2, Layer 3
Form FactorModular chassis
StackableNo
Chassis Slots3, 6, 7, 10
Power Supply OptionsAC, DC
RedundancyPower supply, Supervisor engine
Network ManagementCisco IOS Software CLI, SNMP, Cisco Prime Infrastructure
FeaturesSecurity, QoS
Port DensityUp to 384 ports per chassis
Security Features802.1X, ACLs, DHCP Snooping, Dynamic ARP Inspection, IP Source Guard
Supervisor Engine8-E