EasyManuals Logo

Cisco Catalyst 4500 Series Message Guide

Cisco Catalyst 4500 Series
146 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #133 background imageLoading...
Page #133 background image
2-113
Catalyst 4500 Series Switch Cisco IOS System Message Guide Release 12.2(31)SGA
OL-11541-01
Chapter 2 Messages and Recovery Procedures
SWITCHINGENGINEMAN Messages
Error Message C4K_SWITCHINGENGINEMAN-3-PPELEAKDETECTED: Hardware buffer leak
detected. System will be reset!
Explanation
A PPE leak was detected, and the system will reset. This may be due to a transient
hardware problem with the packet buffer related memories. This message may also erroneously
appear if using jumbo packets or if sharing is configured and transmit queues have backed up.
Recommended Action This is an informational message only. No action is required. To suppress the
automatic reset action use the diagnostic monitor action conservative command.
Error Message C4K_SWITCHINGENGINEMAN-7-PPELEAKMONITOR: Current Freelist count %u.
Fell below threshold %u times consecutively
Explanation
The PPE freelist count is being monitored. Packet buffer leak detection is on and the
freelist count is being monitored. This message displays the current count and number of times the
count reached the threshold. If the freelist count stays below the threshold for more than one minute,
the system will be reset.This message may also erroneously appear if using jumbo packets or if
sharing is configured and transmit queues have backed up.
Recommended Action This is an informational message only. No action is required. To suppress the
automatic reset action use the diagnostic monitor action conservative command.
Error Message C4K_SWITCHINGENGINEMAN-3-RDPMEOPMISMATCHERROR: RdPMEopMismatch error
, subcell addr=[hex], reg bits=[hex], total errors=%u
Explanation
An error in a packet's cell was detected. This could indicate a problem with the packet
cell linked list or subcell count memory. If this message persists, it may indicate a transient hardware
problem, or a more permanent problem. After 1024 such End-Of-Packet mismatch errors, the switch
will reload.
Recommended Action After 1024 such End-Of-Packet mismatch errors, the switch will reload. If the
switch is reloading too often due to this condition, you may need to check for environmental
conditions such as RFI or other interference. It may also be necessary to replace the supervisor
engine.
Error Message C4K_SWITCHINGENGINEMAN-3-SUBCELLCNTMEMORYPARITYERROR: Parity error in
subcell count memory, addr=[hex], reg bits=[hex], total errors=%u
Explanation
An error in subcell count memory was detected. If this message persists, it may indicate
a transient hardware problem, or a more permanent problem. After 128 such subcell count errors,
the switch will reload.
Recommended Action If the switch is reloading too often due to this condition, you may need to check
for environmental conditions such as RFI or other interference. It may also be necessary to replace
the supervisor engine.

Table of Contents

Other manuals for Cisco Catalyst 4500 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Catalyst 4500 Series and is the answer not in the manual?

Cisco Catalyst 4500 Series Specifications

General IconGeneral
SeriesCatalyst 4500 Series
CategorySwitch
Layer SupportLayer 2, Layer 3
Form FactorModular chassis
StackableNo
Chassis Slots3, 6, 7, 10
Power Supply OptionsAC, DC
RedundancyPower supply, Supervisor engine
Network ManagementCisco IOS Software CLI, SNMP, Cisco Prime Infrastructure
FeaturesSecurity, QoS
Port DensityUp to 384 ports per chassis
Security Features802.1X, ACLs, DHCP Snooping, Dynamic ARP Inspection, IP Source Guard
Supervisor Engine8-E