EasyManua.ls Logo

Cisco Nexus 5000 Series - Page 467

Cisco Nexus 5000 Series
660 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Send feedback to nx5000-docfeedback@cisco.com
1-5
Cisco Nexus 5000 Series Switch CLI Software Configuration Guide
OL-16597-01
Chapter 1 Configuring VSAN Trunking
Configuring VSAN Trunking
Figure 1-4 Default Allowed-Active VSAN Configuration
You can configure a selected set of VSANs (from the allowed-active list) to control access to the VSANs
specified in a trunking ISL.
Using Figure 1-4 as an example, you can configure the list of allowed VSANs on a per-interface basis
(see Figure 1-5). For example, if VSANs 2 and 4 are removed from the allowed VSAN list of ISLs
connecting to switch 1, the operational allowed list of VSANs for each ISL would be as follows:
The ISL between switch 1 and switch 2 includes VSAN 1 and VSAN 3.
The ISL between switch 2 and switch 3 includes VSAN 1 and VSAN 2.
The ISL between switch 3 and switch 1 includes VSAN 1, 2, and 5.
Consequently, VSAN 2 can only be routed from switch 1 through switch 3 to switch 2.
V
SANs1, 2, and 3 are o
perational.
VSANs 1, 2, 4,
5areoperationa
l.
VSANs 1 and 2 are operational.
Switch 3
VSAN1
VSAN2
VSAN4
VSAN5
Switch 1
VSAN1
VSAN2
VSAN3
VSAN4
VSAN5
Switch 2
VSAN1
VSAN2
VSAN3
79945