14.3 Environmental
Category
Measures / comments
Operating Temperature
0º C to +40º C, ambient
Storage Temperature
-55º C to +70º C
Humidity, Maximum
90% non-condensing
Table 27: Environmental
14.4 Matrix frame performance
Category
Measures / Comments
Sample Rate
48 kHz
Resolution
24 bit
Frequency Response
@ 48 kHz sampling
30 Hz 22 kHz ± 3 dBu
Crosstalk (adjacent channel)
<70 dBu
Nominal Level
0 dBu
Matrix headroom
+18 dBu
Distortion
<0.05 %, @ 0 dBu, 300 Hz to 10 kHz;
<0.1 %, @ 0 dBu, 100 Hz to 20 kHz
Off Noise
<70 dBu (20 Hz - 22kHz)
On Noise
<65 dBu (20 Hz - 22 kHz)
Key Response, Intra-System
<40 ms for audio route
Table 28: Matrix frame capabilities