User Guide| Eclipse HX-Median
Page 45
Figure 4-12: Wiring the Alarm I/O DB-9F to the Alarm
Relay connector
Figure 4-13: Double-pole double-throw alarm relay
D
General-Purpose Outputs Connector (GP OUT)
A GPO can be programmed to mute a speaker, to turn on an
applause light, to turn on a door lock, or to perform a variety of
other functions. For example, to get the attention of a panel
operator working in a high-noise environment such as a control
booth, a relay can be programmed to switch on a light at the
operator panel each time an incoming call is received, to ensure
that the call is not missed.
Note:
If the GP-OUT port is used on an Eclipse HX-Median matrix
fitted with XP power supplies (part 740101Z) the following filter
must be fitted between the PROC-RCC socket and the cable:
CINCH FA-25PS/1-LF 25W D-type in-line 1000pF filter
(UK supplier: Farnell 111-4108)
If the Eclipse HX-Median matrix is equipped with Power-One
power supplies (part 720379Z) this filter must not be fitted. If
this filter is already fitted to an Eclipse HX-Median matrix and
1
2
9
8
7
6
5
4
3
1
2
3
4
Relay Normally Closed
Relay Wiper
Relay Normally Open
To Alarm
To Alarm
System 200/COM-72
"Alarm I/O" DB-9F
Connector
PSU-101
"Alarm Relay"
Connector