Chapter 5. Diagnostics
203
Error
Message
Cause Solution
Invalid Slot Range
(1-N)
Slot range entered was not a number
between 1 and 8 for the 8-slot shelf; or not
a number between 1 and 12 for the 12-slot
shelf; or not a number between 1 and 24
for the 24-slot shelf; or the first number of
the range was greater than the second
number.
Check the range, then enter the
numbers again. (To check for proper
shelf size, use the SP command.)
LIU B Slot is
Empty
Self explanatory. Informational message only; no action
required.
LIU A Slot is
Empty
Self explanatory. Informational message only; no action
required.
Lower Strobe Card
Not Installed
Self explanatory. Informational message only; no action
required.
Lower Strobe
Error
Self explanatory. Check the lower strobe card and retry
operation.
Map is Working This map is the working map and its
status cannot be modified or changed
while it is the working map.
Make another map the working map
(copy the working map), or choose
another map to modify.
Map Not Enabled A disabled map cannot be made the
working map.
Change the status of the map to
Enabled before making it the working
map.
Original Alarm
Map Working
Only one alarm map can be enabled at a
time. Another alarm map is already
enabled and its status cannot be changed
because it is currently the working map.
Normally, when a second alarm map is
enabled, the first alarm map is disabled,
unless it is the working map.
Change the first alarm map so that it is
not the working map. Then try again to
change the status of the second alarm
map to Enabled.
Original Event
Map Working
Only one event map can be enabled at a
time. Another event map is already
enabled and its status cannot be changed
because it is currently the working map.
Normally, when a second event map is
enabled, the first event map is disabled,
unless it is the working map.
Change the first event map so that it is
not the working map. Then try again to
change the status of the second event
map to Enabled.
Original Time Map
Working
Only one time map can be enabled at a
time. Another time map is already
enabled and its status cannot be changed
because it is currently the working map.
Normally, when a second time map is
enabled, the first time map is disabled,
unless it is the working map.
Change the first time map so that it is
not the working map. Then try again to
change the status of the second time
map to Enabled.
Password Already
Used
Duplicate passwords are not allowed. Select and enter another password.
Password Table
Full
A maximum of eight passwords are
allowed, and eight are already entered.
Delete an already-defined password,
then enter the new password.
Request is Not
Allowed
Self explanatory. Make corrections and retry. If
appropriate, respond to system prompts
to correct the problem.