Chapter 5. Diagnostics
204
Error
Message
Cause Solution
Reinstall Line
Card Error
Power-up sequence of the line card is not
correct.
Install line card again, perhaps with power off.
Switch to Normal
Mode
Self explanatory. Informational message only; no action required.
That Slot Appears
Unoccupied
Operation cannot be performed because
there is no card in the slot, or because
that card is not responding.
Check to see if a card is in the slot. Reseat the
card, then re-enter the command. If the message
continues to be received, replace the card.
This Selection Has
No Meaning For
D4W Card
Self explanatory. Informational message for dual-four wire cards.
Make corrections and retry.
Two Alarm Map
Types Not Allowed
Self explanatory. Informational message. Make corrections and
retry.
Two Event Maps
Cannot Be
Enabled
Only one event map can be enabled at a
time. When a second event map is
enabled, the first event map's status is
changed from Enabled to Disabled.
Informational message. Make corrections and
retry.
Two Time Maps
Cannot Be
Enabled
Only one time map can be enabled at a
time. When a second map is enabled, the
first map's status is changed from Enabled
to Disabled.
Informational message. Make corrections and
retry.
Two Time Maps
With The Same
Time Not Allowed
Self explanatory. Informational message. Make corrections and
retry.
Try Again Self explanatory. Informational message. Make corrections and
retry.
Unsupported Loop
Code
Self explanatory. Informational message only; no action required.
Upper Strobe Card
Not Installed
Self explanatory. Informational message only; no action required.
Upper Strobe
Error
Self explanatory. Check the upper strobe card and retry the
operation.
Working Map Type
Cannot Be
Modified
The map is currently the working map and
cannot be modified while it is the working
map.
Select another map to modify, or make another
map the working map. When the map is no longer
the working map, its type can be changed.