D/I Mux III User’s Manual Appendix I. Traps and Modem Dial Out Configuration
288
] ma
Modify T1 Alarm Trap Conditions
-------------------------------
1 Modify T1 line one criteria
Q Quit
Select: [Q] 1
15:43:37 --------[ Set T1 Line Trap Criteria - T1 One ]-------- 06/19/97
If any alarm marked Check is present, the T1 line will be considered down. Unmarked alarms are ignored.
------------------------------------------------------------------------
0: Receive Far End LOF (Yellow) ..... [ ]
1: Transmit Far End LOF (Yellow) .... [ ]
2: Receive AIS (Blue) ............... [ ]
3: Transmit AIS (Blue) .............. [ ]
4: Near End Loss Of Frame (Red) ..... [ ]
5: Near End Loss Of Signal .......... [ ]
6: Loopback ......................... [ ]
7: Bypass ........................... [ ]
8: Carrier Group Alarm .............. [ ]
9: Delayed Carrier Group Alarm ...... [ ]
A: Any Alarm
N: None
Q: Quit
Chose a number to change the state of that alarm, or chose a letter for
the specified action: [Q] 8.
Figure J-2 Modify alarm Screen