Compliance and Standards Certification
COMPLIANCE AND STANDARDS CERTIFICATION
FCC RF Exposure Requirements
Forinstallations,whichhavetocomplywithFCCRFexposurerequirements,theantennaselectionand
installationmustbecompletedinawaytoensurecompliancewiththoseFCCrequirements.Dependingon
theRFfrequency,ratedoutputpower,antennagain,andthelossbetweentherepeaterandantenna,the
minimumdistanceDtobemaintainedbetweentheantennalocationandhumanbeingsiscalculated
accordingtothisformula:
where
• P(mW)istheradiatedpowerattheantenna,i.e.themax.ratedrepeateroutputpowerinadditiontothe
antennagainminusthelossbetweentherepeaterandtheantenna.
• PD(mW/cm²)istheallowedPowerDensitylimitacc.to47CFR1.1310(B)forgeneralpopulation/
uncontrolledexposureswhichis
– f(MHz)/1500forfrequenciesfrom300MHzto1500MHz
– 1forfrequenciesfrom1500MHzto100,000MHz
RFexposurecompliancemayneedtobeaddressedatthetimeoflicensing,asrequiredbytheresponsibleFCC
Bureau(s),includingantennaco-locationrequirementsof1.1307(b)(3).
EMC Standards
• ForinstallationsthathavetocomplywithEuropeanEN50385exposurecompliancerequirements,the
followingPowerDensitylimits/guidelines(W/m²)accordingtoICNIRParevalid:
– 2forfrequenciesfrom10MHzto400MHz
– f(MHz)/200forfrequenciesfrom400MHzto2GHz
– 10forfrequenciesfrom2GHzto300GHz
• ThisunitcomplieswithEuropeanstandardEN60950.
This is class A equipment. This equipment can cause radio interference in domestic areas. In this case the