Codes Error Description Recommended Action
------------------------------------------------------------------------------
102 - 10 Numeric coprocessor real The following steps apply
number calculation test failed to error codes 102 - 01
through 102 - 15:
102 - 11 Numeric coprocessor speed test
failed 1. Replace the numeric
coprocessor and retest.
102 - 12 Numeric coprocessor pattern 2. Replace the system
test failed board and retest.
102 - 15 Numeric coprocessor inoperative
or socket unoccupied
------------------------------------------------------------------------------
103 - 01 DMA page registers test failed Replace the system board
and retest for error codes
103 - 02 DMA byte controller test failed 103 - 01 through 113 - 01.
103 - 03 DMA word controller test failed
104 - 01 Interrupt controller master test
failed
104 - 02 Interrupt controller slave test
failed
104 - 03 Interrupt controller software RTC
inoperative
------------------------------------------------------------------------------
Error
Codes Error Description Recommended Action
------------------------------------------------------------------------------
105 - 01 Port 61 bit 6 not at zero Replace the system board
and retest for error codes
105 - 02 Port 61 bit 5 not at zero 103 - 01 through 113 - 01.
105 - 03 Port 61 bit 3 not at zero
105 - 04 Port 61 bit 1 not at zero
105 - 05 Port 61 bit 0 not at zero
105 - 06 Port 61 bit 5 not at one
105 - 07 Port 61 bit 3 not at one
105 - 08 Port 61 bit 1 not at one
105 - 09 Port 61 bit 0 not at one
105 - 10 Port 61 I/O test failed
105 - 11 Port 61 bit 7 not at zero
105 - 12 Port 61 bit 2 not at zero
106 - 01 Keyboard controller self test failed