Fire Detection System - CFD5000 T / CM2.2
Installation & Commissioning Manual

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Consilium CFD5000 T/CM2.2 and is the answer not in the manual?

Summary

Introduction

About this manual

Details about the purpose and scope of the Installation & Commissioning Manual.

References

List of related technical product manuals for the CFD5000 T fire detection system.

Symbols used in the manual

Explanation of symbols used to convey warnings, cautions, and notes.

Safety considerations

If a fire or fault alarm is flashing on the control panel

Guidance for handling fire and fault alarms on the control panel.

Precautionary measures

Measures to improve safety and reduce risks during system operation.

Fire Detection System

System Description

Overview of the CFD5000 Fire Detection System and its components.

System data

Technical specifications and data for the CFD5000 fire detection system.

Prerequisites for installation

Electrical Installation

Recommended installation order

Sequence for performing electrical installation tasks for the system.

Cabling and Electrical Installation

Details on cable categories, separation, shielding, and earthing.

Electrical installation, central equipment

Specifics for installing central equipment, including terminal layout.

Mechanical Installation

Recommended installation order

Sequence for performing mechanical installation tasks for the system.

Control panels

Guidelines for installing control panels and their environmental requirements.

Loop units

Information on connecting loop units to the loop-line and environmental requirements.

Loop Units Installation Guidelines

General guidelines for installing various types of loop units.

Pre-commissioning

Inspection

Checklist for inspecting the electrical and mechanical installation.

Test the loop cable

Procedure for testing loop cable resistance and integrity.

Check the loop units

Steps for checking loop units, including address verification.

Commissioning

Commissioning requirements

Prerequisites and required equipment for system commissioning.

Loops (Control Panel CM2.2)

Procedure for verifying loop connectivity and system status.

Setting address and layout on Repeater M4.3

Instructions for setting address and layout for Repeater M4.3.

Testing of System Parts (Control Panel CM2.2)

Procedures for testing various system components and detectors.

Safety validation and acceptance

Fault codes

Fault codes for CFD5000

List of fault codes, their causes, remedies, and failure classifications.

Address list and test report

Appendix A

ID List

Information on setting the ID for address units.

SSP termination

Recommendations for SSP installation and termination.

Appendix B

System modules & connection example

Description of system modules and a connection example.

Appendix C

Definitions and abbreviations

Glossary of terms and abbreviations used in the manual.

Appendix D

The Consist ID

Procedure for updating the Consist ID for SDTv2 communication.

Appendix E

Compatibility matrix

Table showing compatible software versions for modules and loop units.

Revision history

Consilium CFD5000 T/CM2.2 Specifications

General IconGeneral
Operating Voltage10 - 30 VDC
Alarm indicationRed LED
Operating Temperature+70°C
Air Humidity0-95% RH (non-condensing)
Power SupplyExternal power supply required