BS Controller for AC SERVO PRESS
Instruction Manual Ver1.08
BS-M3A-1B
- 59 -
error The measu
re against a noise is required. It is, when the load
sensor connector has fallen out.
1001-1031
The abnormalities
in a program
Abnormalities were detected in the program number
(detailed alarm code -1000).
1101-1131
The abnormalities
in Judge Table
Abnormalities were detected in Judge Table number
(detailed alarm code -1100).
1201-1231
The abnormalities
in Zone Table
Abnormalities were detected in Zone Table number
(detailed alarm code -1200).
1301
The abnormalities
in Position Table
Abnormalities were detected in Position Table.
1302
The abnormalities
in Load Table
Abnormalities were detected in Load Table.
1303
The abnormalities
in Speed Table
Abnormalities were detected in Speed Table.
1304
The abnormalities
in Home Position
Table
Abnormalities were detected in Home Position Table.
1400
The abnormalities
in Tool Table
Abnormalities were detected in Home Tool Table.
1601
The abnormalities
in Numerical data
Abnormalities were detected in the pointer of
Numerical data.
1602
The abnormalities
in Numerical data
Abnormalities were detected in Numerical data.
1603
The abnormalities
in Waveform data
Abnormalities were detected in the pointer of Normal
Waveform data.
1604
The abnormalities
in Waveform data
Abnormalities were detected in Normal Waveform
data.
1605
The abnormalities
in Waveform data
Abnormalities were detected in the pointer of NG
Waveform data.
1606
The abnormalities
in Waveform data
Abnormalities were detected in NG Waveform data.
1701
The abnormalities
in Alarm history
Abnormalities were detected in the pointer of Alarm
history.
1702
The abnormalities
in Alarm history
Abnormalities were detected in Alarm history.
1801
The abnormalities
in Backup time
Abnormalities were detected in Backup time.
1802
The abnormalities
in Total running
times
Abnormalities were detected in Total running times.
1803
The abnormalities
in
Total running
distance
Abnormalities were detected in Total running
distance.
1901-1904
The abnormalities
in Others
Abnormalities were detected in Others.
1905
The abnormalities
in JOG speed
Abnormalities were detected in JOG speed
1906
The abnormalities
in Load/Stroke
output interval
Abnormalities were detected in Load/Stroke output
interval.

Table of Contents