Page 13
TO EXIT PROGRAM MODES
To exit program modes when you have finished programming:
Press <PROGRAM> - <ENTER>
Program light goes out
The panel is now back in Normal Mode, any program changes you have made will have replaced previous values
and be in effect.
Note: During programming Tampers and 24 hour alarms are disabled which allows quiet access to the panel,
detectors and satellite siren units etc. On exiting program mode, all inputs are scanned and if any tampers or 24Hr
alarms are present an activation will occur.
PROGRAMMING USER CODESPROGRAMMING USER CODES
USER CODES - (Address 1 to 10 & 11)
There are 11 codes available in the PowerWave-8, 10 user codes and 1 install code. The user codes are located in
addresses 1-10. As default, Code 1 has Master Code access and must be used to enter Client programming mode.
The Installer code is stored at address 11 and is used to access Installer Programming mode.
Codes 1-10 may be varied in length from 1 to 6 digits. Code 11 must be 3-6 digits.
Below is an example of changing User Code #1 to ‘4567’, and adding User Code #5 as ‘321’
<PROGRAM> - < Installer Code or Master Code> - <ENTER>
<PROGRAM> - <1> - <ENTER>
<4567> - <ENTER>
3 beeps - program light flashing
<PROGRAM> - <5> - <ENTER>
<321> - <ENTER>
3 beeps - program light flashing
To replace a code simply enter the new code in the same address as the old code. This will overwrite the previous
code but maintain the user access as that of the previous code.
To clear or delete a code simply enter the BYPASS button at the address where the old code is stored.
<PROGRAM> - <3> - <ENTER> <BYPASS> <ENTER>
3 beeps - Program light flashing
User Code # 3 is Erased
Note: Where there are multiple options at one address, options ‘0’ will turn all options off and ‘9’ will turn
all options on.