Option Send Restores - When an alarm is generated the panel automatically sends a restore when the alarm
is reset. If the Central Station does not want restores they may be turned off with this option.
Option Spare - Default off
Option Spare - Default off
Option Send Test call to Central Station - The automatic daily test call to a Central Station can be disabled if
not required by turning off this option.
Note: 182 through 184 are as above but applied to telephone numbers 2-4
Maximum Dial Attempts per Telephone Number
The addresses (245-248) are used to select the maximum number of dial attempts the panel will make for each
telephone number
245 Maximum Dial Attempts for Ph # 1 - Value 0-99 (Default = 20)
246 Maximum Dial Attempts for Ph # 2 - Value 0-99 (Default = 20)
247 Maximum Dial Attempts for Ph # 3 - Value 0-99 (Default = 20)
248) Maximum Dial Attempts for Ph # 4 - Value 0-99 (Default = 20)
MISCELLANEOUS PANEL OPTIONSMISCELLANEOUS PANEL OPTIONS
This address (170) is used to select optional miscellaneous panel functions.
170 Œ Panel Tamper NC or EOL - Default off
Installer Lockout - Default off
Ž Disable Mains Fail Test - Default off
Zones aren’t Force Armable - Default off
No audible keypad beep on supervised Wireless fault - Default off
No audible keypad beep for zone Inactivity Timeout - Default off
“Control” button disables Chime Zones - Default off
Silent 24 Hour Alarms (No keypad Buzzer) - Default off
Option Œ Panel Tamper NC or EOL - The Tamper input on the PowerWave control board (Tmp) requires sealing
to clear the panel tamper alarm. If option 1 is on the panel must see a 2k2 resistor (EOL) across the
Tmp & 0V terminals to ensure the tamper is sealed. If this option is turned off the a simple short circuit
(NC) is all that is required to seal the panel tamper.
Option Installer Lockout - Normally, if the panel is unset and powered up with the panel tamper open (in
alarm) then the panel will automatically go into installer program mode. If this option is on, the panel will
not automatically go into program mode and the only valid method of accessing program mode is via the
installer code.
Option Ž Disable Mains Fail Test - If the panel must be run off a DC supply but the supply is too low to be wired
into the AC terminals then this option completely disables the mains fail Monitoring so the panel will not
give a continuous system alarm.
Option Zones are not Force Armable - If this option is on then the panel can only be armed if all zones are
sealed (Bypassing those zones which can be ignored at Address 145)
Option No audible keypad beep on supervised radio fault - If a supervised wireless detector fails to send a
test signal within a preset period, an alarm will be generated. A supervised alarm will cause the system
LED on the keypad to flash. If this option is off then all keypad buzzers will also sound continuously to
warn of the problem. If this option is on, the buzzers will not sound on a supervised alarm but the system
LED will still flash.
Option No audible keypad beep on zone inactivity timeout - If a zone is set for inactivity monitoring
(Address) and it does not unseal at least once during the timeout period (Address 240) an alarm will be
generated. An inactivity timeout will cause the trouble LED on the keypad to flash and the zone led that
failed will be on solid. If this option is off then all keypad buzzers will sound continuously to warn of the
problem. If this option is on, the buzzers will not sound, instead the trouble LED will still flash.