Chirps & Flashes-Partition “A”
This block of addresses sets a number of output options which are specific and unique to the operation of
partition or Area "A". Activity in Areas "B" will have no direct effect on the options set at these addresses.
111 Œ Arm status to output- Default off
Stay Mode on status to output- Default off
Ž Disarm status to output- Default off
Remote Control Chirps (2) for Arm to output - Default off
Remote Control Chirps (2) for Stay Mode On to output - Default off
Remote Control Chirps (4) for Disarm to output - Default off
Pulse on Arming to output - Default off
Pulse on Disarming to output - Default off
Option Œ Arm indication to output - This option will turn the output on when Area "A" is armed. The output
will turn on at the start of the exit delay and turn off when the Area is disarmed. The output reset
time should be set to zero.
Option Stay Mode On indication to output - This option will turn the output on when Area "A" Stay Mode
is armed. The output will turn on at the start of the exit delay and turn off when Stay Mode is
disarmed. The output reset time should be set to zero.
Option Ž Disarm indication to output - This option will turn the output on when Area "A" is Disarmed. The
output will turn on when the Area “A” is disarmed and turn off when the Area is Armed or in Stay
Mode. The output reset time should be set to zero.
Option Remote Control Chirps for Arm to output - This option will map two short pulses (Chirps) to the
output when Area "A" is armed via a Remote Control, ( the length of the pulses is set by the pulse
timer Address 221-228).
Option Remote Control Chirps for Stay Mode On to output - This option will map two short pulses
(Chirps) to the output when Area "A" Stay Mode is set via a Remote Control Button ,( the length of
the pulses is set by the pulse timer Address 221-228).
Option Remote Control Chirps for Disarm to output - This option will map four short pulses (Chirps) to
the output when Area "A" is Disarmed via a R/C Button, ( the length of the pulses is set by the pulse
timer Address 221-228).
Option Pulse on Arming to output - This option will send a pulse to the Output each time Area"A" is
armed ( the length of the pulses is set by the pulse timer Address 221-228).
Option Pulse on Disarming to output - This option will map a pulse to the Output each time Area"A" is
disarmed ( the length of the pulses is set by the pulse timer Address 221-228).
Note: 112 through 118 are as above but applied to outputs 2-8