Page 35
Dialler Reporting Options 2
This address (187) is used to enable or disable various alarm reports to the Dialler.
187 Œ Keypad Panic Alarms - Default on
• Keypad Manual Fire Alarms (4&6) - Default on
Ž Keypad Manual Medical Alarms (7&9) - Default on
• Spare
• Spare
‘ Spare
’ Spare
“ Spare
Option Œ Keypad Panic Alarms - If the single button “Panic” or the 2 button “1&3” Panic alarm features are
enabled then turning this on option allows the Panic Alarm to be sent via the dialler to a Central
Station.
Option • Keypad Fire Alarm - If the 2 button “4&6” Fire alarm feature is enabled then turning this option on
allows the Fire Alarm to be sent via the dialler to a Central Station.
Option Ž Keypad Medical Alarm - If the 2 button “7&9” Medical alarm feature is enabled then turning this option
on allows the Fire Alarm to be sent via the dialler to a Central Station.
Dialler Reporting Options 3
188 Œ Report Open/Close - Default on
• Report Stay Mode Open/Close - Default on
Ž Report Open after alarm - Default off
• Report Stay Open after alarm - Default off
• Report 24 Hour Alarms when set to Domestic/Voice mode - Default off
‘ Send Arm immediately (or after exit delay) - Default off
’ Send Zone alarms in Stay Mode - Default off
“ Spare - Default off
Option Œ Report Open/Close - If this option is on then all Open/Close signals will be reported to a Central Station
if Contact ID is set as the reporting format.
Option • Report Stay Mode Open/Close - If this option is on then all Stay Mode Arm/Disarm signals will be
reported to a Central Station if Contact ID is set as the reporting format.
Option Ž Send Open after alarm - If this option is on, the panel will not normally send an Arm/Disarm signal to
the Central Station, however, if a zone alarm occurs then the panel will send a Disarm following the
disarming of the panel to show it has been turned off by a valid user.
Option • Send Stay Mode unset after activation - If this option is on, the panel will only send a Stay Mode Arm/
Disarm signal to the Central Station if a zone alarm occurs. The panel will send a Disarm and group
bypass restore following the disarming of the panel to show it has been turned off by a valid user.
Option • Report 24 Hour Alarms when set to Domestic/Voice mode - When the panel is set to send alarms via
domestic or voice mode, NO alarms will normally be sent for 24 hour zones. If 24 hour alarms are
required to be reported in Domestic/Voice mode then this option must be turned on.
Option ‘ Send Arm immediately - If this option is on, the arm report is sent immediately the panel is armed. If
the option is turned off, the arm signal will be sent at the expiry of the exit delay timer.
Option ’ Send Zone alarms in Stay Mode - If this option is on, any Stay Mode zone alarms will be reported via
the dialer. If it is off, no Stay Mode zone alarms will be transmitted via the dialer.
Option “ Spare - Default off