5 Freelink with checksum (supervised signal active) - If a Crow Freelink Wireless PIR is used on the
PowerWave Wireless zone input, setting this bit allows the panel to correctly recognize the alarm,
tamper & battery low signal from the device. The automatic supervised signal is sent every 20 minutes.
6 Freelink with checksum (non-supervised) - If a Crow Freelink Wireless PIR is used on the
PowerWave Wireless zone input, setting this bit allows the panel to correctly recognize the alarm,
tamper & battery low signal from the device. The automatic supervised signal sent every 20 minutes by
the PIR is ignored in this mode.
11 Ness Battery Low - If a Ness Wireless pendant or PIR is used on the PowerWave Wireless Receiver,
setting this bit allows the panel to correctly recognize the battery low signal from Ness devices.
12 Ness Radio Reed Switch - If a Ness Wireless Reed Switch is used on the PowerWave Wireless
Receiver, setting this bit allows the panel to correctly recognize the battery low signal from Ness device.
This bit also recognizes the open and closed signals from the reed switch so the zone Led can follow the
correct state of the reed switch (ie open or closed)
21 Electronics Line Wireless PIR- If an Electronics Line Wireless PIR is used on the PowerWave
Wireless Receiver, setting this bit allows the panel to correctly recognize the alarm, tamper & battery low
signal from E.L. device.
NOTE: If you encounter a situation where the Electronics Line Wireless PIR does Not communicate
with the panel, this would be due to the version of the transmitter in the PIR. In such cases, you may try
setting the wireless zone options to “0” for this device. Please be aware that the “0” option does Not
allow for Low Battery or Tamper reporting but at least the Electronics Line Wireless PIR will start
communicating with the panel. (“ON” = Switch 1, “OFF” = Switch 2, 3 & 4)
31 Visonic Wireless PIR- If a Visonic K900 radio PIR is used PowerWave Wireless Receiver, setting this
bit allows the panel to correctly recognize the alarm, tamper & battery low signal from the device.
32 Visonic Powercode (unsupervised) - If a Visonic Powercode Wireless device is used on the
PowerWave Wireless Receiver, setting this bit allows the panel to correctly recognize the alarm and
battery low signal from the device but the supervised signal is ignored.
33 Visonic Powercode (supervised) - If the Visonic Powercode range of Wireless PIR or reed switch are
used on the PowerWave Wireless Receiver, setting this bit allows the panel to correctly recognize the
alarm, tamper & battery low signal from the device. Setting this option on also starts a 4 hour timer for
the supervised signal. The 4 hour timer is constantly being reset while valid supervised signals are being
received every 1-1.5 hours. If no supervised signals are received from the PIR within the 4 hour period,
a supervised alarm is generated.
Note: Addresses 232 through 238 are as above but applied to zones 2-8
Wireless Zone Supervision Timer
239 WIRELESS ZONE SUPERVISED TIMER - Default= 240 Minutes (Value 0-255 Minutes)
Remote Control Button Learning
To learn a Remote Control Button into the panel, press the appropriate address number (e.g. 614 for
Button 4). The keypad buzzer will beep once a second to indicate learn mode has been initiated and the
Led on the RX-40 Receiver board will flash. The Remote Button you wish to learn must transmit a signal
within 30 seconds of entering learn mode otherwise the panel will time out and nothing will be loaded. If
a valid code is received within the 30 seconds the keypad will give 3 short beeps and exit learn mode.
To remove a loaded Remote Button at a single address only, enter in the learning address as above e.g.
614, then without operating the transmitter and before the 30 second timer expires press the “Enter”
button. This will remove the Button loaded against this address.
611 Learn Button # 1
612 Learn Button # 2
613 Learn Button # 3
614 Learn Button # 4
615 Learn Button # 5
616 Learn Button # 6
617 Learn Button # 7
618 Learn Button # 8