140 24 Hour Zone Zones 1-8 ( Default = No zones) Page 24
141 Non-Latching 24 Hour Zone Zones 1-8 ( Default = No zones) Page 25
142 Swinger Shutdown Zones 1-8 ( Default = No zones) Page 25
143 Chime Zone (when disarmed) Zones 1-8 ( Default = No zones) Page 25
144 Permanent Chime Zone Zones 1-8 ( Default = No zones) Page 25
145 Force Arm Zone Zones 1-8 ( Default = No zones) Page 25
146 Send Zone Bypasses to C.S. Zones 1-8 ( Default = All zones) Page 25
147 Send Multiple Alarms to C.S. Zones 1-8 ( Default = All zones) Page 25
148 Send Zone Tampers to C.S. Zones 1-8 ( Default = All zones) Page 25
149 Common Zones Report to Area B Account Zones 1-8 ( Default = No zones) Page 25
150 Zones with Inactivity Timer Zones 1-8 ( Default = No zones) Page 25
Remote Control Arm/Disarm Options
151 R/C Button # 1 Opt (Default= 1,3,4) Page 32
152 R/C Button # 2 Opt (Default= 1,3,4) ŒŒ = Assigned to Area “A” Page 32
153 R/C Button # 3 Opt (Default= 1,3,4) • = Assigned to Area “B” Page 32
154 R/C Button # 4 Opt (Default= 1,3,4) Ž = Can Arm Area Page 32
155 R/C Button # 5 Opt (Default= 1,3,4) • = Can Disarm Area Page 32
156 R/C Button # 6 Opt (Default= 1,3,4) • = Can arm Stay Mode Page 32
157 R/C Button # 7 Opt (Default= 1,3,4) ‘ = Can disarm Stay Mode Page 32
158 R/C Button # 8 Opt (Default= 1,3,4) ’ = Spare Page 32
“ = Disabled if Panel is in Alarm
Remote Control Output Options
161 R/C Button # 1 Options (Default= None) Page 32
162 R/C Button # 2 Options (Default= None) ŒŒ = R/C Button Can Turn Output On Page 32
163 R/C Button # 3 Options (Default= None) • = R/C Button Can Turn Output Off Page 32
164 R/C Button # 4 Options (Default= None) Ž = Visonic Powercode Battery Low Page 32
165 R/C Button # 5 Options (Default= None) • = Spare Page 32
166 R/C Button # 6 Options (Default= None) • = Send Panic Alarm Through Dialler Page 32
167 R/C Button # 7 Options (Default= None) ‘ = Causes Immediate Panic Page 32
168 R/C Button # 8 Options (Default= None) ’ = Causes Delayed Panic ( 1.5 Sec) Page 32
“ = Ness Battery Low
Miscellaneous Panel Options
169 Misc. Panel Options # 1 Page 29
(Default= 3) ŒŒ = Turn KP LED’s when Armed
• = Keypad “Panic” Button instant or delayed
Ž = Direct access to program mode for the installer code.
170 Misc. Panel Options # 2 Page 40
(Default= None) ŒŒ = Panel Tamper NC or EOL
• = Installer Lockout
Ž = Disable Mains Fail Test
• = Arm only if Sealed
• = No audible keypad beep on supervised Wireless fault
‘ = No audible keypad beep on Zone Inactivity Timeout
’ = “Control” Button Disables Chime Zones
“ = Silent 24 Hour Zone (No Keypad Beep)
Keypad Partition
171 Keypads Assigned To Partition “A” - Value Keypad 1-8 (Default= All Keypads) Page 27
172 Keypads Assigned To Partition “B” - Value Keypad 1-8 (Default= No Keypads) Page 27
Keypads with Panic Button Enabled
173 Keypads with Panic Button Enabled - Value Keypad 1-8 (Default= All Keypads) Page 27
Keypads with 1&3 Panic Enabled
174 Keypads with 1 & 3 Panic Function Enabled - Value Keypad 1-8 (Default= No Keypads) Page 27