Page 47
Dialler Reporting Options 3
188 Dialler Options 3 (Default = 1,2) Page 35
ŒŒ = Report Open/Close
= Report Stay Mode Open Close
Ž = Report ‘Open after Alarm’
= Report Stay Mode ‘Open after Alarm’
= Report 24 Hour Alarms when set to Domestic /voice mode
= Send Open immediate or after exit delay
= Report Zone alarms in Stay Mode
= Spare
Keypad Listen-in Options
189 Keypad Listen-in Options (Default = 1-7) Page 37
ŒŒ = Enabled During Dialling in Disarm State only
= Enabled During Dialling in Armed State only
Ž = Enabled During Dialling in Stay Mode State only
= Enabled Throughout the call in Disarm State only
= Enabled Throughout the call in Armed State only
= Enabled Throughout the call in Stay Mode State only
= Listen-in Enabled when the panel answers a call
= Enabled at All Times
Output # 1 Listen-in Options
190 Output # 1 Listen-in Options (Default = None) Page 38
ŒŒ = Enabled During Dialling in Disarm State only
= Enabled During Dialling in Armed State only
Ž = Enabled During Dialling in Stay Mode State only
= Enabled Throughout the call in Disarm State only
= Enabled Throughout the call in Armed State only
= Enabled Throughout the call in Stay Mode State only
= Listen-in Enabled when the panel answers a call
= Enabled at All Times
Output Delay ON time
201 Output 1 Delay ON Time - Value 0-255 Seconds (Default = 0 Sec) Page 18
202 Output 2 Delay ON Time - Value 0-255 Seconds (Default = 0 Sec) Page 18
203 Output 3 Delay ON Time - Value 0-255 Seconds (Default = 0 Sec) Page 18
204 Output 4 Delay ON Time - Value 0-255 Seconds (Default = 0 Sec) Page 18
205 Output 5 Delay ON Time - Value 0-255 Seconds (Default = 0 Sec) Page 18
206 Output 6 Delay ON Time - Value 0-255 Seconds (Default = 0 Sec) Page 18
207 Output 7 Delay ON Time - Value 0-255 Seconds (Default = 0 Sec) Page 18
208 Output 8 Delay ON Time - Value 0-255 Seconds (Default = 0 Sec) Page 18
Chime Mode to Keypad Buzzer Timer
209 Partition “A” Chime Mode to KP Buzzer Time - Value 0-99 1/10 Seconds (Default ; 20 =2 Sec) Page 28
210 Partition “B” Chime Mode to KP Buzzer Time - Value 0-99 1/10 Seconds (Default ; 20 =2 Sec) Page 28
Output Chime Mode Time
211 Output 1 Chime Mode ON Time - Value 0-99 1/10 Seconds (Default ; 20 =2 Sec) Page 29
212 Output 2 Chime Mode ON Time - Value 0-99 1/10 Seconds (Default ; 20 =2 Sec) Page 29
213 Output 3 Chime Mode ON Time - Value 0-99 1/10 Seconds (Default ; 20 =2 Sec) Page 29
214 Output 4 Chime Mode ON Time - Value 0-99 1/10 Seconds (Default ; 20 =2 Sec) Page 29
215 Output 5 Chime Mode ON Time - Value 0-99 1/10 Seconds (Default ; 20 =2 Sec) Page 29
216 Output 6 Chime Mode ON Time - Value 0-99 1/10 Seconds (Default ; 20 =2 Sec) Page 29
217 Output 7 Chime Mode ON Time - Value 0-99 1/10 Seconds (Default ; 20 =2 Sec) Page 29
218 Output 8 Chime Mode ON Time - Value 0-99 1/10 Seconds (Default ; 20 =2 Sec) Page 29
Programming Exit Delays
219 Partition “A” Exit Delay Time - Value 0-255 Seconds (Default = 20 Sec) Page 27
220 Partition “B” Exit Delay Time - Value 0-255 Seconds (Default = 20 Sec) Page 27