Output Timing Options
OUTPUT RESET TIME (0-9999 Seconds)
The output reset time is how long an output will stay on following an alarm condition. A value of “0”
means the output will latch until reset by a valid user code.
311 Output 1 Alarm Reset Time - (Default = 300 Sec)
312 Output 2 Alarm Reset Time - (Default = 0 Sec)
313 Output 3 Alarm Reset Time - (Default = 300 Sec)
314 Output 4 Alarm Reset Time - (Default = 300 Sec)
315 Output 5 Alarm Reset Time - (Default = 0 Sec)
316 Output 6 Alarm Reset Time - (Default = 0 Sec)
317 Output 7 Alarm Reset Time - (Default = 0 Sec)
318 Output 8 Alarm Reset Time - (Default = 0 Sec)
OUTPUT DELAY ON TIME (0-99 Seconds)
The output delay ON time is how long an output will be delayed before turning on following an alarm
condition.
201 Output 1 Delay On Time - (Default = 0 Sec)
202 Output 2 Delay On Time - (Default = 0 Sec)
203 Output 3 Delay On Time - (Default = 0 Sec)
204 Output 4 Delay On Time - (Default = 0 Sec)
205 Output 5 Delay On Time - (Default = 0 Sec)
206 Output 6 Delay On Time - (Default = 0 Sec)
207 Output 7 Delay On Time - (Default = 0 Sec)
208 Output 8 Delay On Time - (Default = 0 Sec)
OUTPUT CHIME MODE TIME (0-99 1/10th Second)
The output Chime mode timer is how long an output will turn on following a Chime zone unsealing.
The Chime Mode Timer is in 1/10th Sec intervals e.g. 20=2 Seconds
211 Output 1 Chime Mode Time - (Default = 20)
212 Output 2 Chime Mode Time - (Default = 20)
213 Output 3 Chime Mode Time - (Default = 20)
214 Output 4 Chime Mode Time - (Default = 20)
215 Output 5 Chime Mode Time - (Default = 20)
216 Output 6 Chime Mode Time - (Default = 20)
217 Output 7 Chime Mode Time - (Default = 20)
218 Output 8 Chime Mode Time - (Default = 20)
OUTPUT PULSE TIMER- (0-99 1/10th Second)
The output pulse timer is how long an output will turn on when the pulse timer is used. The Pulse
Timer is in 1/10th Sec intervals eg 20=2 Seconds
221 Output 1 Pulse Timer - (Default = 20)
222 Output 2 Pulse Timer - (Default = 20)
223 Output 3 Pulse Timer - (Default = 20)
224 Output 4 Pulse Timer - (Default = 20)
225 Output 5 Pulse Timer - (Default = 20)
226 Output 6 Pulse Timer - (Default = 20)
227 Output 7 Pulse Timer - (Default = 20)
228 Output 8 Pulse Timer - (Default = 20)