Page 28
KEYPAD PROGRAMMINGKEYPAD PROGRAMMING
Keypad Partition
A keypad must be assigned to a Partition before it can control the Partition (ie to allow Arm/Disarm
facilities).
171 Keypads Assigned to Partition “A” - Option Keypad 1-8 (Default = All keypads 1-8)
172 Keypads Assigned to Partition “B” - Option keypad 1-8 (Default = None)
Keypads with Panic Button enabled
The panic button on all keypads can be set for delayed or instant operation. If you do not want the
Panic function enabled at any of the keypads you can disable the operation at this address. This
option may be useful where a keypad has to be installed in a public area.
173 Keypads with the Panic Button Enabled - Option keypad 1-8 (Default = All keypads 1-8)
Keypads with Buttons 1&3 Panic enabled
An alternative Panic function to the dedicated panic button is to press the keypad buttons 1&3
simultaneously. If you do not want this Panic function enabled at any of the keypads you can disable
the operation at this address. This option may be useful where a keypad has to be installed in a
public area.
174 Keypads with the Panic Buttons 1&3 Enabled - Option keypad 1-8 (Default = None)
Panic Alarm to Keypad Buzzer
The two panic functions at the keypads (Address 173 or 174) can be audible or silent at the keypads.
If a silent panic is required the option must be turned off at this address. For an audible Panic Beep
at the keypad/s turn this option on.
175 Panic Alarm to Keypad Buzzer - Option keypad 1-8 (Default = All keypads 1-8)
Keypads with Buttons 4&6 Fire Enabled
By pressing the buttons 4&6 simultaneously it is possible to create a Fire alarm report to the dialler. If
you want this Fire function enabled at any of the keypads you must enable the operation at this
address.
176 Keypads with the Panic Buttons 4&6 Enabled - Option keypad 1-8 (Default = None)
Fire Alarm to Keypad Buzzer
The two button fire function at the keypads (Address 176) can be audible or silent at the keypads. If a
silent fire alarm is required the option must be turned off at this address. For an audible Panic Beep
at the keypad/s turn this option on.
177 Fire Alarm to Keypad Buzzer - Option keypad 1-8 (Default = None)
Keypads with Buttons 7&9 Medical Enabled
By pressing the buttons 7&9 simultaneously it is possible to create a Medical alarm report to the
dialler. If you want this Medical function enabled at any of the keypads you must enable the operation
at this address.
178 Keypads with the Medical Buttons 7&9 Enabled - Option keypad 1-8 (Default = None)