Keypad/Keyswitch Options-Partition “B”
This address allows modification of how Partition “B” arming, Stay and control keys work at the keypad.
120 Œ “ARM” button required before code to set- Default off
“STAY” button required before code to turn on Stay Mode- Default off
Ž Disable “ARM” Button- Default off
“ARM” button can disarm system during exit delay- Default on
“STAY” button can disarm Stay Mode at any time- Default on
No Exit Beeps to keypads in Stay Mode- Default off
Key-switch Enabled- Default off
Key-switch Mode- Default off
Option Œ “ARM” button required before code to set - This option determines if the “ARM” button must be
pressed before a code is entered to set Area “B”. If a keypad is assigned to both Partitions, this
option should be set to allow individual arming of each area. This option disables the Arm button from
disarming during the exit delay.
Option “STAY” button required before code to set - This option determines if the “STAY” button must be
pressed before a code is entered to set Area “B” Stay Mode. If a keypad is assigned to both
Partitions, this option should be set to allow individual arming of Stay Mode for each area.
Option Ž If this option is set, the “ARM” button is disabled and the panel requires a code to arm as well as
disarm.
Option ARM” button can disarm during exit delay - If this option is on then the “Arm” button can disarm
Partition “B” during the exit delay time with a single press of the button. If the option is off then the
alarm can only be unset by a valid code, even during the exit delay time.
Option “STAY” button can disarm Stay Mode - This option allows the “Stay” button to disarm Stay mode
at any time (including when Stay Mode is fully set). If the option is off then Stay Mode can only be
unset by a valid code. This feature is valid for keypad addresses 1 & 4 by default (4 being the default
address for the Stay key station).
Option No Exit Beeps to keypads in Stay Mode - This option stops the exit beeps from occurring at all
keypads when Stay Mode is set. Normally used for silent night arming.
Option Enable Partition “B” Key-switch - If this option is turned on then the system tamper input (Tmp)
becomes a Dual End of Line Input (Refer to Page 6 for wiring details). The high input 8K2 is reserved
for Partition “B” key-switch operation. An open circuit will still be seen as a system tamper.
Option Key-switch Mode - If this option is On then the key-switch has a toggle function (ie the arm/disarm
state will follow the key-switch state). If Off then the key-switch is momentary (ie each single pulse
will change the arm/disarm state). The panel tamper input is used to provide the key-switch function.