Option “CONTROL” function disables Chime zones - This option will disable the Chime zone Monitoring
when “Control” is on. It is used to stop Chime zone beeps from occurring at the keypad or operating an
output when not needed. To initiate the “Control” function the operator must press The “Control” button
followed by the “Program” button. When the “Control” function is On the Program LED will flash.
Option Silent 24 Hour Alarms (No keypad Buzzer) - If this option is on then any 24 hour alarms (Address
129,140 or 141) will not cause the keypad buzzer to sound i.e. silent alarm.
Setting Real Time Clock
The Real Time Clock is used to Time & Date stamp the events in the Event Buffer. Ensure this is set correctly at the
time of installation so that the events have the proper time and date associated with them. The clock is programmed
in 24 hour format (e.g. 00:00-23:59).
401 Real Time Clock Hour/Minute - Value 0-2359
403 Real Time Clock Day of Week - Value 1-7 (where 1 = Sunday, 2 = Monday, 3 = Tuesday, etc)
405 Real Time Clock Date - Value 1-31
406 Real Time Clock Month - Value 1-12
407 Real Time Clock Year - Value 0-99
Default Entire Panel
620) Restore Factory Defaults
Default Selected Parts of Panel
621 Default User Codes
622 Default Addresses 20-199
623 Default Addresses 200-399
624 Default Addresses 500-599
625 Default Wireless Detectors & Remote Controls
Clear Alarm Memory
626 Clear Alarm Memory Buffer
Walk Test Mode
This address (627) is used to enable walk-test mode while in installer program mode. When entering this address,
the keypad buzzer will beep at 1 second intervals to indicate walk-test mode is active. By walking past all of the
detectors connected to the system and activating them, the associated zone light will latch up at the keypad to allow
verification that all zones are working properly. By pressing the “Program” or “Enter” buttons, walk-test mode can be
terminated and normal programming resumed.
627 Walk-test Mode
Write to EEPROM Programming Board
This address (628) is used to copy the panels program configuration to an external EEProm memory card which can
be plugged into the expansion socket on the control board. An onboard Jumper can be removed to stop the re-writing
of data.
628 Write to EEPROM (DTU) Board
Read from EEPROM Programming Board
This address (629) is used to return the panels program configuration from an external EEProm memory card which
can be plugged into the expansion socket on the control board. An onboard Jumper can be removed to stop the re-
writing of data.
629 Read from EEPROM Programming Board