Page 44
Keypad/Keyswitch Option Partition “A”
110 Partition “A” Options 110 Options Page 20
(Default= 4 & 5) ŒŒ = Arm Button Required Before Code to Set
• = Stay Button Required Before Code to Set Stay Mode
Ž = Code required to Set
• = Arm Button can disarm during Exit Delay
• = Stay Button can disarm Stay Mode at any time
‘ = No Exit beeps to Keypads in Stay Mode
’ = Enable Key-switch
“ = Key-switch Mode
Chirps & Flashes-Partition “A”
111 Area “A” Opt. O/P # 1 (Default= None) Page 22
112 Area “A” Opt. O/P # 2 (Default= None ŒŒ = Arm Status to Output
113 Area “A” Opt. O/P # 3 (Default= None) • = Stay Arm Status to Output
114 Area “A” Opt. O/P # 4 (Default= None) Ž = Disarm Status to Output
115 Area “A” Opt. O/P # 5 (Default= None) • = R/C Chirps on Arm
116 Area “A” Opt. O/P # 6 (Default= None) • = R/C Chirps on Stay Mode Arm
117 Area “A” Opt. O/P # 7 (Default= None) ‘ = R/C Chirps on Disarming
118 Area “A” Opt. O/P # 8 (Default= None) ’ = Pulse on Arming to Output
“ = Pulse on Disarming to Output
Keypad/Keyswitch Option Partition “B”
120 Partition “B” Options Page 21
(Default= 4 & 5) ŒŒ = Arm Button Required Before Code to Set
• = Stay Button Required Before Code to Set Stay Mode
Ž = Code required to Set
• = Arm Button can disarm during Exit Delay
• = Stay Button can disarm Stay Mode at any time
‘ = No Exit beeps to Keypads in Stay Mode
’ = Enable Key-switch
“ = Key-switch Mode
Chirps & Flashes-Partition “B”
121 Area “B” Opt. O/P # 1 (Default= None) Page 23
122 Area “B” Opt. O/P # 2 (Default= None) ŒŒ = Arm Status to Output
123 Area “B” Opt. O/P # 3 (Default= None) • = Stay Arm Status to Output
124 Area “B” Opt. O/P # 4 (Default= None) Ž = Disarm Status to Output
125 Area “B” Opt. O/P # 5 (Default= None) • = R/C Chirps (2) on Arm
126 Area “B” Opt. O/P # 6 (Default= None) • = R/C Chirps (2) on Stay Mode Arm
127 Area “B” Opt. O/P # 7 (Default= None) ‘ = R/C Chirps (4)_on Disarming
128 Area “B” Opt. O/P # 8 (Default= None) ’ = Pulse on Arming to Output
“ = Pulse on Disarming to Output
Programming Zone Doubling & EOL Options
130 Single EOL or Zone Doubling - Value 1-8 (Default = 1-4 On, 4 Zone panel with 2k2 EOL) Page 26
Programming Zone Options
129 24 Hour Fire Zone Zones 1-8 ( Default = No zones) Page 24
131 Partition “A” Zones Zones 1-8 ( Default = All zones) Page 24
132 Partition “B” Zones Zones 1-8 ( Default = No zones) Page 24
133 Zone is NC or NO Zones 1-8 ( Default = All zones are NC) Page 24
134 Wireless Zones Zones 1-8 ( Default = No zones) Page 24
135 Zone is Bypassable Zones 1-8 ( Default = All zones) Page 24
136 Auto-Isolate Zone Zones 1-8 ( Default = All zones) Page 24
137 Handover Zone Zones 1-8 ( Default = No zones) Page 24
138 Pulse Count on Zone Zones 1-8 ( Default = No zones) Page 24
139 Stay Mode Zone Zones 1-8 ( Default = Zone 1) Page 24