Page 32
Remote Control Arm/Disarm Options
This block of addresses (151 - 158) are used to select the operational settings for each of the 8 Remote Control
Buttons. Functions such as arm only, disarm only or both can be selected for each button independently.
151-Button #1 Options Œ Assigned to Partition “A” - Default on
Assigned to Partition “B” - Default off
Ž Can Arm - Default on
Can Disarm - Default on
Can turn Stay Mode On - Default off
Can turn Stay Mode Off - Default off
Spare - Default off
Disabled if panel is in alarm - Default off
Option Œ Assigned to Partition “A” - The R/C Button must be assigned to at least one partition to allow it to
perform arm/disarm functions. The Button can be assigned to both partitions if required.
Option Assigned to Partition “B” - The R/C Button must be assigned to at least one partition to allow it to
perform arm/disarm functions. The Button can be assigned to both partitions if required.
Option Ž Can Arm - This option assigns the Arm function to a Button. The partition/s it will arm have to be
selected at options 1 & 2.
Option Can Disarm - This option assigns the Disarm function to a Button. The partition/s it will disarm has to be
selected at options 1 & 2.
Option Can turn Stay Mode On - This option assigns the Stay Mode Arm function to a Button. The partition/s it
will arm has to be selected at options 1 & 2. If Stay Mode arming is to be used for this Button then
Options 2 & 3 should be turned off.
Option Can turn Stay Mode Off - This option assigns the Stay Mode Disarm function to a Button. The
partition/s it will disarm has to be selected at options 1 & 2. If Stay Mode disarming is to be used for this
Button then Options 2 & 3 should be turned off.
Option Spare
Option Disabled if panel is in Alarm - This option stops the Button from working while the panel is in alarm.
This feature should only be set if you feel that a Button with disarming functions could be prone to
misuse in an alarm condition.
Note: Addresses 152 through 158 are as above but applied to Buttons 2-8
Remote Control Output Options
This block of addresses (161 - 168) are used to select output control and Panic options for each of the 8 R/C Buttons.
To prevent confusion, if a Buttons is set to control an output or provide instant Panic, then you should turn off any
Arm or Disarm options at addresses 151-158.
161-Button #1 Options Œ Turn output ON - Default off
Turn output OFF - Default off
Ž Visonic Powercode Battery Low - Default off
Spare - Default off
Hold Down Button Panic will Dial - Default off
Hold Down Button Immediate Panic Alarm - Default off
Hold Down Button Delayed Panic Alarm (1.5 Seconds) - Default off
Ness Battery Low - Default off
Option Œ Turn Output On - This option allows the Button to turn an output on. The output the Button will turn On
is programmed at address 101-108. If the output reset time is set to Latched operation (set to “0”) then
you must also program Option 2 to allow for turning the output Off.