Output Pulse Time
221 Output 1 Pulse Time - Value 0-99 1/10 Seconds (Default ; 20 =2 Sec) Page 19
222 Output 2 Pulse Time - Value 0-99 1/10 Seconds (Default ; 20 =2 Sec) Page 19
223 Output 3 Pulse Time - Value 0-99 1/10 Seconds (Default ; 20 =2 Sec) Page 19
224 Output 4 Pulse Time - Value 0-99 1/10 Seconds (Default ; 20 =2 Sec) Page 19
225 Output 5 Pulse Time - Value 0-99 1/10 Seconds (Default ; 20 =2 Sec) Page 19
226 Output 6 Pulse Time - Value 0-99 1/10 Seconds (Default ; 20 =2 Sec) Page 19
227 Output 7 Pulse Time - Value 0-99 1/10 Seconds (Default ; 20 =2 Sec) Page 19
228 Output 8 Pulse Time - Value 0-99 1/10 Seconds (Default ; 20 =2 Sec) Page 19
Zone Pulse Count Timer
229 Zone Pulse Count Timer - Value 0-255 Seconds (Default = 60 Sec) Page 26
Duress Digit
230 Duress Digit - Value 1-9 (Default = 0 Duress Function Disabled) Page 14
Wireless Detector Options
231 Options for Zone # 1 (Default= 0) 0 = For Unknown Devices - no low batt or Tmp Page 29
232 Options for Zone # 2 (Default= 0) 1 = Crow AE Series Battery low Page 29
233 Options for Zone # 3 (Default= 0) 2 = Crow AE Radio Reed Switch Page 29
234 Options for Zone # 4 (Default= 0) 3 = Crow Merlin PIR (supervised signal ignored) Page 29
235 Options for Zone # 5 (Default= 0) 4 = Crow Merlin PIR (supervised signal active) Page 29
236 Options for Zone # 6 (Default= 0) 11 = Ness Devices battery Low Page 29
237 Options for Zone # 7 (Default= 0) 12 = Ness Radio Reed Switch Page 29
238 Options for Zone # 8 (Default= 0) 21 = Electronics Line ‘Cougar’ Wireless PIR Page 29
(“ON” = Switch 1, “OFF” = Switch 2, 3 & 4)
31 = Visonic K900 Wireless PIR Page 29
32 = Visonic Powercode (supervised signal ignored) Page 29
33 = Visonic Powercode (supervised signal active)
Wireless Detector Supervision Timer
239 Wireless Detector Supervision Timer - 0-255 Minutes (Default = 240 Minutes) Page 30
Zone Inactivity Timer
240 Zone Inactivity Timer - 0-255 Hours (Default = 120 Hours) Page 22
Dialling Protocol
241 Phone # 1 (Default= 1) ŒŒ = Contact ID Page 38
242 Phone # 2 (Default= None) = Domestic Dial Page 38
243 Phone # 3 (Default= None) Ž= Pager Page 38
244 Phone # 4 (Default= None) = Speech Dialler Page 38
Maximum Dialling Attempts per Phone Number
245 Maximum re-Tries for PH No. 1 - Value 0-99 (Default = 20) Page 40
246 Maximum re-Tries for PH No. 2 - Value 0-99 (Default = 20) Page 40
247 Maximum re-Tries for PH No. 3 - Value 0-99 (Default = 20) Page 40
248 Maximum re-Tries for PH No. 4 - Value 0-99 (Default = 20) Page 40
Auto-Answer Ring Count
249 Auto-Answer Ring Count - Value 0-99 (Default = 25) Page 37
Start Message Number for DTMF Telephone Control
250 Start of DTMF Telephone Control Messages - Value 0-99 (Default = 0) Page 35