Option • Turn Output Off - This option allows the Button to turn an output off. The output the Button will turn Off
is programmed at address 101-108. For this option to work, option 1 must also be assigned to the Button
to allow the Button to first turn the output on before it can turn it off.
Option Ž Visonic Powercode Battery Low - If a Visonic Powercode Transmitter with battery low Staying is used
on the PowerWave-8, setting this option will allow the battery signal to be correctly recognised.
Option • Spare
Option • Report Panic to Dialler- This option enables a panic alarm from a R/C Button to be sent via the dialler
to a Staying Station.
Option ‘ Immediate Panic Alarm - If this option is on, pressing the Button will produce a panic alarm.
Option ’ Delayed Panic Alarm- If this option is on, the Button must be pressed continuously for 1.5 seconds or
longer to produce a panic alarm.
Option “ Ness Battery Low - If using a Ness Remote with battery low reporting, this option must be turned on to
allow the battery low signal to be recognised properly.,
Note: Addresses 162 through 168 are as above but applied to Buttons 2-8
DIALLER PROGRAMMING SECTION
Dialler OptionsDialler Options
185 Œ Dialler is Enabled - Default off
• Fax/Answer Machine Defeat (Double Call) - Default off
Ž Disable Telephone Line Monitoring - Default off
• Spare - Default off
• Spare - Default off
‘ Spare - Default off
’ Auto-detect Modem - Default on
“ Bell 103 or V21 - Default off
Option Œ Dialler is Enabled - If this option is turned off the dialler will be disabled. The option must be on to allow
the dialler to make calls.
Option • Fax Defeat - The panel can answer an in-coming call in two ways. The first is to set the auto-answer
ring count to a convenient number (Address 249) and let the phone ring until this number is reached at
which time the panel will answer the call. The second method is to use fax defeat which entails calling
the panel and letting it ring no more than 3 times, hanging up, then ringing back within 45 seconds. The
panel will now answer the call on the first ring.
Option Ž Disable Telephone line Monitoring - If the panel is connected to a poor telephone line and the line
failure alarm is appearing regularly, by turning this option on the panel will not do the line test.
Option • Spare
Option • Spare
Option ‘ Spare
Option ’ Auto-detect Modem - If this option is on the panel will answer an in-coming call with the V21
acknowledge tone. If the modem does not respond within 5 seconds the panel will then generate the
acknowledge tones for Bell 103 format. It will repeat this cycle twice and then hang-up if no
communication with a modem is established.
Option “ Bell 103 or V21 - The dial up panel to PC link can be established using either Bell 103 or V21. If the
auto-detect function at option 7 does not result in the best format for your modem then you can force the
panel to only communicate in one format. If the LED is off the format is Bell 103, LED on means V21.