95XF series Inspection and adjustment
EXPLANATORY NOTES ON THE MAINTENANCE ACTIVITIES
3-11
Adjusting the valve clearance
1. Slacken the lock nut of the adjusting bolt.
2. Using a feeler gauge and special tool (DAF
no. 1240043), adjust the specified valve
clearance, see “Technical data”.
3. Tighten the adjusting bolt using special tool
(DAF no. 1240043) before removing the
feeler gauge.
The s pecified torque is 0.56 - 0.68 Nm.
M2140
4. Hold the adjusting bolt in this position, and
tighten the lock nut using special tool (DAF
no. 1240042) to the specified tightening
torque, see “Technical data”.
M2141
5
200424