Page #183 background image
User's Manual
163
smoking detection rules for the visible light channel of a thermal camera.
Smoking alarm is only available with AI by Camera.
6.11.1 Enabling AI Plan
Enable the corresponding AI plan before using AI by camera functions. For details, see "6.2.1
Enabling AI Plan".
6.11.2 Configuring Smoking Alarm
Configure smoking alarm rules.
Step 1 Click or click on the configuration page, and then select EVENT.
Step 2 In the device tree, select the thermal channel of a thermal camera.
Step 3 Select AI Application > Smoking Alarm.
Step 4 Click next to Enabled to enable rule configuration.
Figure 6-138 Configure smoking alarm
Step 5 Set Sensitivity and Min Duration.
Sensitivity: The higher the
Sensitivity is, the easier the call action is detected.
Min Duration: The minimum duration the call action lasts. If the call action still lasts
after the
Min Duration, the system will trigger an alarm.
Step 6 Click
Deployment Time to select a schedule from the drop-down list.
System triggers corresponding alarm actions only during the alarm deployment period.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dahua Technology IVSS Series and is the answer not in the manual?

Dahua Technology IVSS Series Specifications

General IconGeneral
BrandDahua Technology
ModelIVSS Series
CategoryDVR
LanguageEnglish

Related product manuals