WARNING: When setting up the camera’s power supplies follow these guidelines
ï‚· Apply the appropriate voltages.
ï‚· Protect the camera with a 2 amp slow-blow fuse between the power supply and the camera.
ï‚· Do not use the shield on a multi-conductor cable for ground.
ï‚· Keep leads as short as possible in order to reduce voltage drop.
ï‚· Use high-quality linear supplies in order to minimize noise.
Note: If your power supply does not meet these requirements, then the camera performance specifications are not
guaranteed.
Ethernet Connector and Ethernet LED
The camera uses an RJ45 connector and a standard Cat 5 cable for Gigabit Ethernet signals and serial
communications. The device supports 10/ 100/ 1000 Mbit/ s speeds.
Note: Router connection not supported. Connection to a network switch for a single camera is supported.
Ethernet Connection LED
Steady ON indicates that an Ethernet connection is successfully established at 1Gbps.
Data Transmission LED
Steady ON indicates that the camera is ready for data transmission. Flashing indicates that the camera is
transmitting or receiving data.
EMC Compliance
In order to achieve EMC compliance, the Spyder3 camera requires the use of shielded CAT5e or CAT6
Ethernet cables.
Status LED
The camera is equipped with a red/ green LED used to display the status of the camera's operation. The
table below summarizes the operating states of the camera and the corresponding LED states.
When more than one condition is active, the LED indicates the condition with the highest priority. Error
and warning states are accompanied by corresponding messages that further describe the current camera
status.