15-62 Option Ordering No
Array [8]
Range: Function:
0* [0 - 8 ] Shows the ordering number for the installed
options.
15-63 Option Serial No
Array [8]
Range: Function:
0* [0 - 18 ] View the installed option serial number.
15-70 Option in Slot A
Range: Function:
0* [0 - 30 ] View the type code string for the option installed
in slot A, and a translation of the type code string.
For example, type code string AX means no
option.
15-71 Slot A Option SW Version
Range: Function:
0* [0 - 20 ] View the software version for the option installed
in slot A.
15-72 Option in Slot B
Range: Function:
0* [0 - 30 ] View the type code string for the option installed
in slot B, and a translation of the type code string.
For example, for type code string BX, the
translation is No option.
15-73 Slot B Option SW Version
Range: Function:
0* [0 - 20 ] View the software version for the option installed
in slot B.
15-74 Option in Slot C0/E0
Range: Function:
0* [0 - 30 ] View the type code string for the option installed
in slot C, and a translation of the type code string.
For example, type code string CXXXX means no
option.
15-75 Slot C0/E0 Option SW Version
Range: Function:
0* [0 - 20 ] View the software version for the option installed
in slot C.
15-76 Option in Slot C1/E1
Range: Function:
0* [0 - 30 ] Shows the type code string for the options
(CXXXX if there is no option).
15-77 Slot C1/E1 Option SW Version
Range: Function:
0* [0 - 20 ] Software version for the installed option in option
slot C.
15-80 Fan Running Hours
Range: Function:
0 h* [0 - 2147483647 h] This parameter shows how many
hours the external fan has run. The
value is saved when the frequency
converter is turned o.
3.14.11 15-9* Parameter Info
15-92 Dened Parameters
Range: Function:
0* [0 - 9999 ] View a list of all dened parameters in the
frequency converter. The list ends with 0.
15-93 Modied Parameters
Range: Function:
0* [0 - 9999 ] View a list of the parameters that have been
changed from their default setting. The list ends
with 0. Changes may not be visible until up to
30 s after implementation.
15-98 Drive Identication
Range: Function:
0* [0 - 40 ]
15-99 Parameter Metadata
Array [30]
Range: Function:
0* [0 - 9999 ] This parameter contains data used by the MCT
10 Set-up Software tool.
Parameter Description
VLT
®
AQUA Drive FC 202
148 Danfoss A/S © 05/2018 All rights reserved. MG20OB02
33

Table of Contents

Other manuals for Danfoss VLT AQUA Drive FC 202

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT AQUA Drive FC 202 and is the answer not in the manual?

Danfoss VLT AQUA Drive FC 202 Specifications

General IconGeneral
BrandDanfoss
ModelVLT AQUA Drive FC 202
CategoryDC Drives
LanguageEnglish

Related product manuals