Manual Datafox Evo 4.3 Page 45 Date: 27.12.2017 V 04.03.09.XX
5.5.3.6. 2 mal digital Out - 2 times digital out
Connection example:
(Connection of a signal light and a signal horn via a potential-free contact):
5.5.3.7. 1 time digital Out 1x digital IN
Connectiom example (Connection of a signal light and a door contact):
5.5.3.8. 4 times digital IN
Connectiom example (Connection of 4 contacts):
max. 42V AC /
2A / 60W
max. 42V AC / 2A / 60W
e.g .: Door contact
max. 30V
0 - 1,5 V Input logical 0
3,5 V - 30 V Input logical 1
e.g.: 4x digital in
max. 30V
0 - 1,5 V Input logical 0
3,5 V - 30 V Input logical 1