Symbologies Enter/Exit Programming Mode
Product Reference Guide  
          183
Plessey Set Length 1
This feature specifies one of the bar code lengths for Plessey Length Control. Length 1 is the 
minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length 
Mode. Length includes the bar code’s data characters only. The length can be 
set from 01 to 50 
characters.
Tabl e 23 provides some examples for setting Length 1. See page 253 for detailed instructions on 
setting this feature.
Table 23. Plessey Length 1 Setting Examples
STEP ACTION EXAMPLES
1 Desired Setting 01 Characters 07 Characters 15 Characters 50 Characters
2 Scan ENTER/EXIT PROGRAMMING MODE
3 Scan SELECT Plessey LENGTH 1 SETTING
4
Scan Two Characters From 
Appendix E, Keypad
 ‘0’ and ‘1’  ‘0’ and ‘7’ ‘1’ and ‘5’ ‘5’ AND ‘0’
5 Scan ENTER/EXIT PROGRAMMING MODE
Select Plessey Set Length 1 Setting
Make a mistake? Scan the CANCEL bar code to abort and 
not save the entry string. You can then start again at the 
beginning.
CANCEL
DEFAULT
01 = Length 1 is 1 Character