Data Format Enter/Exit Programming Mode
Product Reference Guide
63
No Read Message
This feature Enables/Disables the No Read Message feature. When Disabled, nothing is sent if
the trigger is pressed and released when no code has been decoded during a reading phase.
Otherwise, the No Read String is sent. (See "No Read String" on page 263 to configure No
Read String
data)
$CNRSS00\r
Disabled
DEFAULT
$CNRSS01\r
Enabled
No Read String
This feature defines the string or character to be displayed in case of No Read during a reading
phase (On Line and Serial On Line Modes only). It allows up to 20 characters, from the set of
ASCII characters or any hex value from 00 to FE.
$CNORS
Select No Read String
To configure this feature, scan th
e ENTER/EXIT PROGRAMMING
MODE barcode above, then the barcode at left followed by the
digits (in hex) from the Alphanumeric characters in
Appendix
E Keypad
representing your desired character(s). If less than
the expected string of 20 characters are selected, scan the
ENTER/EXIT b
arcode to terminate the string.End by scanning
the ENTER/EXIT barcode again.
Make a mistake? Scan the CANCEL barcode to abort and not
s
a
ve the entry string. You can then start again at the beginning.
~
CANCEL
DEFAULT
0x18 = (CAN)
See "No Read String" on page 263 for more information on setting this feature.