EasyManua.ls Logo

Datalogic Gryphon I GFS4400 - Digital Output

Datalogic Gryphon I GFS4400
324 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Digital Output References
Product Reference Guide
265
Digital Output
Output Activation:
Digital Output can set to be Activated/Deactivated when specified events occur.
Line State:
Selects whether the line is Active Low or Active High.
Activation Event:
Selects the event the line is activated on. Selectable events: Disabled, Good
Read, No Read, Right Code, Wrong Code. Right Code and Wrong Code are available only if
Code Verifier functionality is enabled.
Deactivation Event:
Selects the event the line is deactivated on. Selectable events: Disabled,
Timeout, Reading Phase On.
Deactivation Timeout:
Related to the previous parameter, sets the deactivation timeout for the
output.