Enter/Exit Programming Mode RS-232/USB-Com Interfaces
34
Gryphon™ I GFS4400
ACK NAK Timeout Value
This option specifies the amount of time the reader waits for an ACK character from the host 
following label transmission. The selectable timeout range is 200 milliseconds to 15,000ms (15 
seconds) in 200ms increments. A selection of 0 disables the timeout. 
See page 248 for more information on setting th
is feature.
Select ACK NAK Timeout Value Setting
To configure this feature, scan the ENTER/EXIT 
PROGRAMMING MODE bar code above, then the 
bar code at left followed by the digits from the 
Alphanumeric characters in Appendix E, Keypad 
representing your desired character(s). End by 
scanning the ENTER/EXIT 
bar code again.
Make a mistake? Scan the CANCEL bar code to
 abort and 
not save the entry string. You can then start again at the 
beginning.
CANCEL
01 ACK NAK Timeout value is 200ms
ACK NAK Retry Count
This feature specifies the number of times the reader retries a label transmission due to a retry 
condition. The selectable range is from 1 to 254 retries. A selection of 0 disables the count, and 
a selection of 255 specifies unlimited retries. See page 249 for more information.
Select ACK NAK Retry Count Setting
To configure this feature, scan the ENTER/EXIT 
PROGRAMMING MODE bar code above, then the 
bar code at left followed by the digits from the 
Alphanumeric characters in Appendix E, Keypad 
representing your desired character(s). End by 
scanning the ENTER/EXIT 
bar code again.
Make a mistake? Scan the CANCEL bar code to
 abort and 
not save the entry string. You can then start again at the 
beginning.
CANCEL
DEFAULT